Skip to content
StandbyWise

Hub — Generac Next Generation · Power Zone 200

Generac Next Generation Error Codes

Plain-English meanings for the fault codes of Generac's Next Generation Series (10–28 kW) and its Power Zone 200 controller — verified against Generac's own support articles and the Next Generation owner's manual, never copied from dealer blogs. This family is kept strictly separate from the Guardian (Evolution) codes: the two controllers share some code numbers, use different thresholds for others, and clear faults differently. The complete Next Generation table exists in exactly one manufacturer source — Generac's dealer-code article — and the Next Generation owner's manual prints no numeric table at all, only alarm names.

Know the code already?

The Fault Code Lookup tool searches this Next Generation table as its own labeled group — try a code inside a range (for example 3302) and you will get the single 3301–3304 family entry Generac actually publishes, not an invented split.

The Power Zone 200 controller

The Power Zone 200 (also printed 'PowerZone 200') controller was introduced in April 2025 and replaces the Evolution 2.0 controller. It runs Generac's Next Generation air-cooled standby generators (10–28 kW).

What it does, per Generac: utility sensing (loss and reconnection); starting and stopping the generator; power transfer; voltage regulation; exercise scheduling; battery charging (charger integrated into the power zone 200 control panel; and operates as a smart charger).

Modes: AUTO — automatically starts and powers the home on utility loss · MANUAL — starts the engine but does not transfer power unless utility fails · OFF — generator will not start even on utility loss · SERVICE — remains off for maintenance/testing; suppresses alerts and notifications; prevents remote start/stop; disables Mobile Link notifications and FOTA updates while enabled

No display — codes live in Mobile Link

NO screen/display — unlike Evolution and Nexus panels, which included a digital display. Error messages and numeric codes can only be viewed in the Mobile Link app (Mobile Link displays both the message and the numeric code); Field Pro app is the technician/installer tool and is also where fuel selection is configured at setup.

How to clear a code — and what not to do

Press and hold the OFF button for three seconds to clear an alarm, then press AUTO to return to automatic mode. The owner's manual Quick Reference adds: 'Press and hold OFF button for at least 3 seconds to clear an active alarm. Red LED will become solid when the alarm is cleared.' This DIFFERS from Evolution: Guardian/Evolution clearing is OFF, then ENTER twice, then AUTO — Generac's Auxiliary Shutdown article explicitly warns: 'The Power Zone 200 controller uses a different alarm-clearing process than the Evolution controller. Do not use the Guardian Series OFF/ENTER sequence for this controller.' Warnings (yellow) are not dismissed by clearing: a warning must be resolved before the message will clear; the yellow warning light clears itself when the underlying issue is resolved.

Do not use the Guardian OFF/ENTER sequence on a Power Zone 200. On Power Zone 200, an alarm is cleared by pressing and holding the OFF button for three seconds, then pressing AUTO. Do NOT use the Guardian OFF/ENTER sequence on this controller — Generac explicitly warns against it. Warnings are not dismissed by clearing: a warning stays until the underlying issue is resolved, and then clears itself.

The lights: flashing yellow is the Next Generation tell

On Guardian units a warning is a solid yellow light. On Next Generation units a warning or maintenance reminder is a flashing yellow light — and a solid yellow light instead means the unit is running in MANUAL mode. An alarm is a solid red light on both series, but note that a solid red light also appears when a Next Generation unit is simply OFF, where it can be mistaken for an alarm.

Alarm = solid RED (also: a solid red light appears when the generator is OFF — can be mistaken for an alarm). Warning / maintenance reminder = YELLOW: Next Generation shows a FLASHING yellow light for a warning or maintenance due, and a SOLID yellow light while running in MANUAL mode (Guardian, by contrast, shows solid yellow for warnings). Owner's manual External LED Indicators table records combined states (e.g. OFF+ALARM = flashing red; AUTO+ALARM = solid green / flashing red; Emergency Shutdown = flashing red; SERVICE = solid blue plus the applicable status color; controller firmware update = all lights flashing counterclockwise; ECM firmware update = all lights flashing clockwise).

For the full LED picture across series, see the Generac status-lights guide.

The full Next Generation table

All 49 entries from Generac's Next Generation table, plus the two auxiliary-shutdown codes (2800/2801) verified for Next Gen by Generac's dedicated article and the owner's manual. Entries with their own verified thresholds or dedicated Generac articles have their own pages; the ECM-style ranges are covered by this table only, exactly as Generac publishes them.

CodeDisplayed alarmMessage in Mobile Link
502Missing Config - Parameter GroupAlarmA critical configuration parameter has not been set. Please contact a dealer.
504Missing Config - Fuel TypeAlarmA critical configuration parameter has not been set. Please contact a dealer.
505Invalid Serial NumberAlarmA critical configuration parameter has not been set. Please contact a dealer.
1000-1006Controller FaultAlarmCovered in this tableThe generator has experienced an internal alarm on the controller. Please contact a dealer.
1100OvercrankAlarmThe generator has experienced an overcrank alarm. Please contact a dealer.
1200-1208OverspeedAlarmThe generator has experienced an overspeed alarm. Please contact a dealer.
1522RPM SensorAlarmThe generator has experienced a no crank RPM Sensor alarm. Please contact a dealer.
1600UnderspeedAlarmThe generator has experienced an underspeed alarm. Please contact a dealer.
1800-1801OvervoltageAlarmCovered in this tableThe generator has experienced an overvoltage alarm. Please contact a dealer.
1900-1907UndervoltageAlarmThe generator has experienced an undervoltage alarm. Please contact a dealer.
2070Keypad MissingAlarmThe controller board is not recognizing the keypad. Please contact a dealer.
2075Quadclops MissingWarningThe generator does not recognize the external LED lights connection. Please contact a dealer.
2090Model ID Sync FailedWarningA model configuration setting has failed to sync with controller.
2094-2099Wiring ErrorAlarmCovered in this tableThe generator sensing-wire connections to a remote emergency shutdown switch have been miswired. Please contact a dealer. / The generator sensing-wire connections to the transfer switch have been miswired. Please contact a dealer.
2095Fuel Type Sync FailedWarningA model configuration setting has failed to sync with controller.
2100Overload Remove LoadAlarmThe generator has experienced an overload alarm. Please contact a dealer.
2115AVR PWM OverloadAlarmThe generator has experienced an AVR PWM alarm. Please contact a dealer.
2116Generator kW Overload (3-phase nodes only)AlarmGenerac leaves the Mobile Link message blank for this code.
2117Phase kW Overload (3-phase nodes only)AlarmGenerac leaves the Mobile Link message blank for this code.
2120Serial Num Sync FailedWarningA model configuration setting has failed to sync with controller.
2125Run Hours Sync FailedWarningA model configuration setting has failed to sync with controller.
2126Low Oil LevelWarningGenerac leaves the Mobile Link message blank for this code.
2670CANBus ErrorAlarmThe generator has experienced a CANBus alarm. Please contact a dealer.
2750Low BatteryWarningThe battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer.
2751Very Low BatteryAlarmThe battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer.
2760Battery ProblemWarningThe battery is not charging properly. Please replace the battery or contact a dealer.
2770Charger WarningWarningThe battery is not charging properly. Please replace the battery or contact a dealer.
2780Charger Missing ACWarningThe unit is not charging the battery properly. Please contact a dealer.
2790SEEPROM AbuseWarningThe generator has experienced an internal warning on the controller. Please contact a dealer.
2800Auxiliary Shutdown (owner's manual Quick Reference name: SHUTDOWN SWITCH (2800))AlarmType as printed: ALARM (dedicated article: flashing red status indicator may accompany the alarm)Possible alarm messages per dedicated article: 'STOPPED - ALARM / ERROR CODE 2800' or 'SHUTDOWN SWITCH (2800)'
2801Auxiliary Shutdown — remote/secondary switch (owner's manual Quick Reference name: SHUTDOWN SWITCH (2801))AlarmType as printed: ALARM (flashing red)Generac leaves the Mobile Link message blank for this code.
3000ECU FaultedAlarmThe generator has experienced an engine alarm. Please contact a dealer.
3100-3117Engine Throttle Valve 1 Position 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed — the table gives both types for this range)The generator has experienced an engine alarm. Please contact a dealer. / The generator has experienced an engine warning. Please contact a dealer.
3200-3217Engine Fuel Delivery PressureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced an engine high fuel pressure alarm. / …an engine low fuel pressure alarm. / …an engine fuel pressure alarm. / …an engine high fuel pressure warning. / …an engine low fuel pressure warning. (each ending 'Please contact a dealer.')
3301-3304Engine Oil PressureAlarmThe generator has experienced an engine low oil pressure alarm. Please contact a dealer. / The generator has experienced an engine oil pressure alarm. Please contact a dealer.
3400-3417Engine Intake Manifold #1 PressureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)High intake manifold pressure alarm / low intake manifold pressure alarm / intake manifold pressure alarm / high intake manifold pressure warning / low intake manifold pressure warning (each '…Please contact a dealer.')
3500-3517Engine Intake Manifold 1 TemperatureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced a low intake manifold temperature alarm. Please contact a dealer. / The generator has experienced a low intake manifold temperature warning. Please contact a dealer.
3803-3817Battery Potential / Power Input 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced a battery voltage alarm. Please contact a dealer. / The generator has experienced a battery voltage warning. Please contact a dealer.
4101Engine Position SensorAlarmThe generator has experienced an engine primary sync loss. Please contact a dealer.
4201Engine Timing SensorAlarmThe generator has experienced an engine secondary sync loss. Please contact a dealer.
4300-4317O2 SensorAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced an O2 sensor alarm. Please contact a dealer. / The generator has experienced an O2 sensor warning. Please contact a dealer.
4503-4507Engine Ignition Coil #1AlarmCovered in this tableThe generator has experienced an engine ignition coil alarm. Please contact a dealer.
4603-4607Engine Ignition Coil #2AlarmCovered in this tableThe generator has experienced an engine ignition coil alarm. Please contact a dealer.
4900-4917Engine Fuel Valve 1 PositionAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced an engine fuel valve alarm. Please contact a dealer. / The generator has experienced an engine fuel valve warning. Please contact a dealer.
5100-5117Engine SpeedAlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced an engine speed alarm. Please contact a dealer. / The generator has experienced an engine speed warning. Please contact a dealer.
5200-5217Cylinder Head Temperature 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed)The generator has experienced a cylinder head temperature alarm. Please contact a dealer. / The generator has experienced a cylinder head temperature warning. Please contact a dealer.
5303-5304Engine Fuel Shutoff 2 ControlAlarmCovered in this tableThe generator has experienced an engine fuel shutoff control alarm. Please contact a dealer.
5415-5417Engine Oil LevelWarningCovered in this tableThe generator has a high oil level warning. Remove loads, let generator cool, check oil level and drain oil if necessary before restarting. If alarm reappears, please contact a dealer. / The generator has a low oil level warning. Remove loads, let generator cool, check oil level and add oil if necessary before restarting. If alarm reappears, please contact a dealer. (Mobile Link text as printed, including its 'before resetarting' typo in the high-level variant, normalized here to 'before restarting')
7000Overload CooldownWarningThe generator has experienced an overload and is in cool down mode. If condition persists, contact a dealer.

Codes 3803–3817 — what the battery-voltage range costs

The 3803–3817 range (“Battery Potential / Power Input 1”) is verified as a battery-voltage family in Generac's own dealer-code table, but Generac publishes nothing more about it — no trigger, no owner action, no part. Its cost block is therefore a dealer-tier block only, stated as plainly as the battery codes that do have pages:

What it costs — codes 3803–3817

Free fix — none documented
No free fix is documented. Generac publishes no trigger threshold, no self-clear condition, and no owner action for this range. The Mobile Link message for this family tells the owner to contact a dealer.
The part

No owner-replaceable part is identified for this family in any Generac source. Generac does not split the individual codes inside this range, so no part can be named for a single code inside it.

At a dealer

No published price exists for this fault family.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What the table-only ranges cost

The remaining ranges in the table above have no page of their own, so their cost blocks live here, stated at range level exactly as Generac publishes the ranges. Most are dealer-tier only: Generac prints no trigger, no owner action, and no part for them, and no published price exists for any single one — each block states that directly, with the same published diagnostic figures the code pages carry. The one exception is 5415–5417 (Engine Oil Level), whose own Mobile Link messages print the owner's oil-level actions.

What it costs — codes 1000-1006 (Controller Fault)

Free fix — none documented
No free fix is documented. The Mobile Link message reports an internal alarm on the controller and tells the owner to contact a dealer.
The part

No part is priced for this range. The controller is integrated and model-specific, and Generac publishes no part number for it.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 1800-1801 (Overvoltage)

Free fix — none documented
No free fix is documented. This is a table-level entry with a dealer-directed message. Generac's Guardian table lists 1800 only — that overlap is shown, not merged.
The part

Generac publishes no part number for this code, so no part can be priced for it.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 2094-2099 (Wiring Error)

Free fix — none documented
No free fix is documented. Both Mobile Link messages for this range end with “Please contact a dealer.” Wiring correction is qualified-technician work, and we publish no wiring information for this family.
The part

Generac publishes no part number for this code, so no part can be priced for it.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 3100-3117 (Engine Throttle Valve 1 Position 1)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. Throttle components are dealer-level remedies, and Generac publishes no part number for them.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 3200-3217 (Engine Fuel Delivery Pressure)

Free fix — none documented
No free fix is documented. Generac publishes no per-code thresholds for this range.
The part

No part is priced for this range. Fuel-system pressure work is dealer-level, and no part number is published.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 3400-3417 (Engine Intake Manifold #1 Pressure)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. The sensor family is named without part numbers in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 3500-3517 (Engine Intake Manifold 1 Temperature)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. The sensor family is named without part numbers in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 4300-4317 (O2 Sensor)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. Generac publishes no O2 sensor part number for it.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 4503-4507 (Engine Ignition Coil #1)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. Ignition coils are named without part numbers in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 4603-4607 (Engine Ignition Coil #2)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. Ignition coils are named without part numbers in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 4900-4917 (Engine Fuel Valve 1 Position)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. The fuel valve is named without a part number in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 5100-5117 (Engine Speed)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

Generac publishes no part number for this code, so no part can be priced for it.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 5200-5217 (Cylinder Head Temperature 1)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. The sensor family is named without part numbers in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 5303-5304 (Engine Fuel Shutoff 2 Control)

Free fix — none documented
No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
The part

No part is priced for this range. The fuel shutoff control is named without a part number in Generac's sources.

At a dealer

No published price exists for this fault.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

What it costs — codes 5415-5417 (Engine Oil Level)

$0 — if correcting the oil level resolves it
Generac's own table prints the owner actions in this range's Mobile Link messages. High level: remove loads, let the generator cool, check the oil level, and drain oil if necessary before restarting. Low level: remove loads, let the generator cool, check the oil level, and add oil if necessary before restarting. Either message ends the same way: if the alarm reappears, contact a dealer. Generac does not assign which code inside this range is high and which is low. If correcting the oil level resolves it and the warning does not reappear, the cost is $0.
The part

For the low-level case, the owner purchase is top-up oil.

Generac 5W-20 GEO full synthetic engine oil (top-up)Part number: A0001412864 (case of 12 quarts, per Generac parts manuals)

  • UGPUS lists it at $18.50 per quart (list $22.99).
  • Conversion of Energy lists it at $20.75 per quart (a secondary figure).
  • Next Generation capacity with filter: 1.4 quarts (10 kW), 2.5 quarts (14/18 kW), 2.2 quarts (22–28 kW).
At a dealer

Per Generac's own messages, a warning that reappears after the oil level is corrected goes to a dealer.

Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).

No dealer price specific to this family is published. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

Ranges stay ranges

Much of the Next Generation table is engine-control (ECM-style) code ranges — 3100–3117, 3200–3217, 3301–3304, and a dozen more. Generac publishes each range under one displayed alarm with combined alarm/warning message variants and does not say what distinguishes the individual codes inside a range. Sites that list a separate meaning for, say, 3302 versus 3303 are going beyond Generac's own publications. Where a range matters most we give it a page of its own — 3301–3304 Engine Oil Pressure is the Next Gen counterpart of Guardian's 1300 — and the rest stay in the table above.

3301 / 3302 / 3303 / 3304 individual meanings: UNVERIFIED — verified negative: no Generac source read separates them; only the 3301-3304 range, one displayed alarm ('Engine Oil Pressure'), ALARM type, and two Mobile Link message variants are published. No psi threshold for the Next Gen oil-pressure family was found in a Generac source.

Individual codes inside every ECM-style range (3100-3117, 3200-3217, 3400-3417, 3500-3517, 3803-3817, 4300-4317, 4503-4507, 4603-4607, 4900-4917, 5100-5117, 5200-5217, 5303-5304, 5415-5417) and inside 1000-1006: UNVERIFIED — Generac publishes these as ranges with combined ALARM/WARNING types and message variants only. The ranges' structure resembles SPN/FMI-style engine codes, but Generac does not say so, so no FMI-style split is inferred.

Guardian codes that do NOT carry over

Code 1300 — Guardian only

Guardian Low Oil Pressure. ABSENT from the Next Generation table; Next Gen oil pressure is 3301-3304. Do not apply 1300 to Next Gen.

Code 1500-1521 — Guardian only

Guardian RPM Sensor range per the dealer-code table. Next Gen's RPM code is 1522 only.

Code 1400 — Guardian only

Guardian High Temperature — no 1400 row in the Next Gen table (Next Gen temperature faults appear as the ECM families 3500-3517 / 5200-5217, and the owner's manual names a HIGH TEMPERATURE alarm without a number). Do not assign 1400 to Next Gen.

Guardian owners: code 1300 Low Oil Pressure and the RPM Sense Loss family page cover the Guardian side.

Shared with Guardian — and overlaps we refuse to merge

A code counts as shared here only where a Generac source itself applies it to the Next Generation line with the same alarm and meaning. Seven codes meet that bar:

CodeAlarmEvidence (per Generac)Pages
1100OvercrankDealer-code article: Next Gen table '1100', Guardian table '1100, 1101', both ALARM/Overcrank. Dedicated Overcrank article Environment: 'Generac Guardian series and Next Generation Air-Cooled Standby series', one meaning (cranks 5 times without starting). NOTE the asymmetry: 1101 is Guardian-only as printed.Next Gen · Guardian
1600UnderspeedDealer-code article: Next Gen '1600', Guardian '1600, 1603', both ALARM/Underspeed. 1603 is Guardian-only as printed.Next Gen · Guardian
2100Overload Remove LoadDealer-code article: both tables list 2100 ALARM (Guardian table also shows a 2100-2103 row). Next Gen owner's manual Quick Reference gives the same owner action for the name.Next Gen · Guardian
2750Low BatteryBattery-alarms article Environment covers Next Generation 10-28 kW AND Guardian 10-26 kW with one trigger (below 12.1 VDC). Also in both dealer-code tables. Generac's articles also conflict on this code's type — see Conflicts and discrepancies.Next Gen · Guardian
2760Battery ProblemBattery-alarms article (both series): >16 V or charger current >600 mA at end of an 18-hour charge cycle. In both dealer-code tables as WARNING.Next Gen · Guardian
2770Charger WarningBattery-alarms article (both series): below 12.5 V at end of an 18-hour charge cycle. In both dealer-code tables as WARNING.Next Gen · Guardian
2780Charger Missing ACDedicated 2780 article covers both series (T1 circuit, expected 120 VAC) — BUT with documented Next Gen differences: Mobile Link-only display on Next Gen, and the Next Gen nuisance-warning behavior. Shared code, series-specific behavior.Next Gen · Guardian

Four more cases overlap without a Generac source asserting the two series' entries are identical, so we record them as overlaps only:

  • 1200-1207 overlap (Overspeed): Next Gen table prints 1200-1208; Guardian prints 1200-1207; the dedicated Overspeed article is titled 1200-1207 and covers both series. The overlapping range is very likely shared, but because the Next Gen table's printed range differs, the overlap is shown as an overlap only, not asserted as an identical-meaning shared range.
  • 1900-1906 overlap (Undervoltage): Next Gen table prints 1900-1907; Guardian prints 1900-1906; dedicated article (both series) lists 1900-1906 under a 1900-1916 title. Same treatment as Overspeed.
  • 1800 (Overvoltage): Guardian table lists 1800 alone; Next Gen lists 1800-1801. 1800 appears in both under the same alarm name/type, but no Generac source states the Next Gen 1800 is the same fault as the Guardian 1800 — shown as overlap only.
  • 2098/2099 vs 2094-2099 (Wiring Error): Guardian lists 2098 and 2099 individually; Next Gen lists the range 2094-2099 with two Mobile Link messages. Same displayed alarm name; per-code identity NOT asserted.

Where Generac's own sources disagree

Generac's articles do not always agree with each other. We preserve every conflict we found as a labeled conflict — on the affected code pages and here — instead of silently picking a winner:

2750 Low Battery type. Dealer-code Next Gen table: 2750 = WARNING. Battery-alarms article: 'Low Battery' WARNING (below 12.1 VDC). BUT Generac's code-list article's message table categorizes the Low Battery 2750 row as 'Alarm | Red | Battery Alarms'. Two Generac articles disagree on type/LED for 2750; the dedicated battery article and the Next Gen table (WARNING) are given precedence in the entry, and the conflict is shown rather than resolved silently.
Overspeed range. Next Gen table: 1200-1208. Guardian table and dedicated article title: 1200-1207. Shown as printed in each source.
Undervoltage range. Next Gen table: 1900-1907. Guardian table: 1900-1906. Dedicated article title: 1900-1916; article body lists 'Error codes: 1900-1906'. Three different extents across Generac sources; shown as printed.
2095 double-listing. In Generac's own Next Gen table, 2095 is both a standalone WARNING row (Fuel Type Sync Failed) and inside the 2094-2099 ALARM range (Wiring Error). Shown as printed.
2800/2801 absent from the dealer-code table. The Auxiliary Shutdown codes do not appear in the Next Generation table of 'What Error Codes Do I Need to Call a Dealer For?' as fetched, but are verified for Next Gen by the dedicated Auxiliary Shutdown article's explicit Next Generation/Power Zone 200 section and the Next Gen owner's manual Quick Reference (SHUTDOWN SWITCH (2800)/(2801)).
Next Gen battery hardware spec (context for the battery-code family). An unresolved Generac-vs-Generac conflict: the Next Gen owner's manual specifies a BTX20L battery, A0006487350, 310 CCA minimum, while other Generac sources (support accessories article + Next Gen spec sheets) specify a Group 30L AGM, 400 CCA (A0010137451/A0010137452) with a 30L tray kit. Likely a model-year/revision difference. The battery CODES in this dataset (2750/2751/2760/2770/2780, 3803-3817) are voltage/charge-state based and are unaffected, but per-size battery fitment is not asserted.
Owner's manual names without table codes. The Next Gen owner's manual Quick Reference names HIGH TEMPERATURE, LOW VOLTS REMOVE LOAD and STEPPER OVERCURRENT alarms (all red) that have no corresponding displayed-alarm row in the dealer-code Next Gen table. No codes were assigned to them.

Alarm names in the owner's manual — with no code

The Next Generation owner's manual (10-28 kW) Section 5 Quick Reference Guide lists alarm NAMES (no numeric codes, except the two shutdown switches) with LED, problem, action and solution. Names: HIGH TEMPERATURE (red), OVERLOAD REMOVE LOAD (red), RPM SENSE LOSS (red), LOW OIL PRESSURE (red), OVERCRANK (red), LOW VOLTS REMOVE LOAD (red — no corresponding displayed alarm in the dealer-code Next Gen table under that exact name; do not assign it a code), OVERSPEED (red), UNDERVOLTAGE (red), UNDERSPEED (red), STEPPER OVERCURRENT (red — likewise no Next Gen table row under that name; the Guardian-era stepper code is not imported), WIRING ERROR (red), OVER-VOLTAGE (red), SHUTDOWN SWITCH (2800) (flashing red), SHUTDOWN SWITCH (2801) (flashing red), LOW BATTERY (yellow), BATTERY PROBLEM (yellow), CHARGER WARNING (yellow), CHARGER MISSING AC (yellow), SERVICE A / SERVICE B / SERVICE C (yellow, maintenance), INSPECT BATTERY (yellow, maintenance reminder).

Battery and upkeep for Next Generation

Sources

Safety note: StandbyWise publishes lookup information only — no gas-line, transfer-switch wiring, or internal repair instructions. Dangerous faults are gated to licensed-dealer referral on every code page. See our disclaimer.