Hub — Generac Next Generation · Power Zone 200
Generac Next Generation Error Codes
Plain-English meanings for the fault codes of Generac's Next Generation Series (10–28 kW) and its Power Zone 200 controller — verified against Generac's own support articles and the Next Generation owner's manual, never copied from dealer blogs. This family is kept strictly separate from the Guardian (Evolution) codes: the two controllers share some code numbers, use different thresholds for others, and clear faults differently. The complete Next Generation table exists in exactly one manufacturer source — Generac's dealer-code article — and the Next Generation owner's manual prints no numeric table at all, only alarm names.
Know the code already?
The Fault Code Lookup tool searches this Next Generation table as its own labeled group — try a code inside a range (for example 3302) and you will get the single 3301–3304 family entry Generac actually publishes, not an invented split.
The Power Zone 200 controller
The Power Zone 200 (also printed 'PowerZone 200') controller was introduced in April 2025 and replaces the Evolution 2.0 controller. It runs Generac's Next Generation air-cooled standby generators (10–28 kW).
What it does, per Generac: utility sensing (loss and reconnection); starting and stopping the generator; power transfer; voltage regulation; exercise scheduling; battery charging (charger integrated into the power zone 200 control panel; and operates as a smart charger).
Modes: AUTO — automatically starts and powers the home on utility loss · MANUAL — starts the engine but does not transfer power unless utility fails · OFF — generator will not start even on utility loss · SERVICE — remains off for maintenance/testing; suppresses alerts and notifications; prevents remote start/stop; disables Mobile Link notifications and FOTA updates while enabled
No display — codes live in Mobile Link
NO screen/display — unlike Evolution and Nexus panels, which included a digital display. Error messages and numeric codes can only be viewed in the Mobile Link app (Mobile Link displays both the message and the numeric code); Field Pro app is the technician/installer tool and is also where fuel selection is configured at setup.
How to clear a code — and what not to do
Press and hold the OFF button for three seconds to clear an alarm, then press AUTO to return to automatic mode. The owner's manual Quick Reference adds: 'Press and hold OFF button for at least 3 seconds to clear an active alarm. Red LED will become solid when the alarm is cleared.' This DIFFERS from Evolution: Guardian/Evolution clearing is OFF, then ENTER twice, then AUTO — Generac's Auxiliary Shutdown article explicitly warns: 'The Power Zone 200 controller uses a different alarm-clearing process than the Evolution controller. Do not use the Guardian Series OFF/ENTER sequence for this controller.' Warnings (yellow) are not dismissed by clearing: a warning must be resolved before the message will clear; the yellow warning light clears itself when the underlying issue is resolved.
The lights: flashing yellow is the Next Generation tell
On Guardian units a warning is a solid yellow light. On Next Generation units a warning or maintenance reminder is a flashing yellow light — and a solid yellow light instead means the unit is running in MANUAL mode. An alarm is a solid red light on both series, but note that a solid red light also appears when a Next Generation unit is simply OFF, where it can be mistaken for an alarm.
Alarm = solid RED (also: a solid red light appears when the generator is OFF — can be mistaken for an alarm). Warning / maintenance reminder = YELLOW: Next Generation shows a FLASHING yellow light for a warning or maintenance due, and a SOLID yellow light while running in MANUAL mode (Guardian, by contrast, shows solid yellow for warnings). Owner's manual External LED Indicators table records combined states (e.g. OFF+ALARM = flashing red; AUTO+ALARM = solid green / flashing red; Emergency Shutdown = flashing red; SERVICE = solid blue plus the applicable status color; controller firmware update = all lights flashing counterclockwise; ECM firmware update = all lights flashing clockwise).
For the full LED picture across series, see the Generac status-lights guide.
The full Next Generation table
All 49 entries from Generac's Next Generation table, plus the two auxiliary-shutdown codes (2800/2801) verified for Next Gen by Generac's dedicated article and the owner's manual. Entries with their own verified thresholds or dedicated Generac articles have their own pages; the ECM-style ranges are covered by this table only, exactly as Generac publishes them.
| Code | Displayed alarm | Message in Mobile Link |
|---|---|---|
| 502 | Missing Config - Parameter GroupAlarm | A critical configuration parameter has not been set. Please contact a dealer. |
| 504 | Missing Config - Fuel TypeAlarm | A critical configuration parameter has not been set. Please contact a dealer. |
| 505 | Invalid Serial NumberAlarm | A critical configuration parameter has not been set. Please contact a dealer. |
| 1000-1006 | Controller FaultAlarmCovered in this table | The generator has experienced an internal alarm on the controller. Please contact a dealer. |
| 1100 | OvercrankAlarm | The generator has experienced an overcrank alarm. Please contact a dealer. |
| 1200-1208 | OverspeedAlarm | The generator has experienced an overspeed alarm. Please contact a dealer. |
| 1522 | RPM SensorAlarm | The generator has experienced a no crank RPM Sensor alarm. Please contact a dealer. |
| 1600 | UnderspeedAlarm | The generator has experienced an underspeed alarm. Please contact a dealer. |
| 1800-1801 | OvervoltageAlarmCovered in this table | The generator has experienced an overvoltage alarm. Please contact a dealer. |
| 1900-1907 | UndervoltageAlarm | The generator has experienced an undervoltage alarm. Please contact a dealer. |
| 2070 | Keypad MissingAlarm | The controller board is not recognizing the keypad. Please contact a dealer. |
| 2075 | Quadclops MissingWarning | The generator does not recognize the external LED lights connection. Please contact a dealer. |
| 2090 | Model ID Sync FailedWarning | A model configuration setting has failed to sync with controller. |
| 2094-2099 | Wiring ErrorAlarmCovered in this table | The generator sensing-wire connections to a remote emergency shutdown switch have been miswired. Please contact a dealer. / The generator sensing-wire connections to the transfer switch have been miswired. Please contact a dealer. |
| 2095 | Fuel Type Sync FailedWarning | A model configuration setting has failed to sync with controller. |
| 2100 | Overload Remove LoadAlarm | The generator has experienced an overload alarm. Please contact a dealer. |
| 2115 | AVR PWM OverloadAlarm | The generator has experienced an AVR PWM alarm. Please contact a dealer. |
| 2116 | Generator kW Overload (3-phase nodes only)Alarm | Generac leaves the Mobile Link message blank for this code. |
| 2117 | Phase kW Overload (3-phase nodes only)Alarm | Generac leaves the Mobile Link message blank for this code. |
| 2120 | Serial Num Sync FailedWarning | A model configuration setting has failed to sync with controller. |
| 2125 | Run Hours Sync FailedWarning | A model configuration setting has failed to sync with controller. |
| 2126 | Low Oil LevelWarning | Generac leaves the Mobile Link message blank for this code. |
| 2670 | CANBus ErrorAlarm | The generator has experienced a CANBus alarm. Please contact a dealer. |
| 2750 | Low BatteryWarning | The battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer. |
| 2751 | Very Low BatteryAlarm | The battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer. |
| 2760 | Battery ProblemWarning | The battery is not charging properly. Please replace the battery or contact a dealer. |
| 2770 | Charger WarningWarning | The battery is not charging properly. Please replace the battery or contact a dealer. |
| 2780 | Charger Missing ACWarning | The unit is not charging the battery properly. Please contact a dealer. |
| 2790 | SEEPROM AbuseWarning | The generator has experienced an internal warning on the controller. Please contact a dealer. |
| 2800 | Auxiliary Shutdown (owner's manual Quick Reference name: SHUTDOWN SWITCH (2800))AlarmType as printed: ALARM (dedicated article: flashing red status indicator may accompany the alarm) | Possible alarm messages per dedicated article: 'STOPPED - ALARM / ERROR CODE 2800' or 'SHUTDOWN SWITCH (2800)' |
| 2801 | Auxiliary Shutdown — remote/secondary switch (owner's manual Quick Reference name: SHUTDOWN SWITCH (2801))AlarmType as printed: ALARM (flashing red) | Generac leaves the Mobile Link message blank for this code. |
| 3000 | ECU FaultedAlarm | The generator has experienced an engine alarm. Please contact a dealer. |
| 3100-3117 | Engine Throttle Valve 1 Position 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed — the table gives both types for this range) | The generator has experienced an engine alarm. Please contact a dealer. / The generator has experienced an engine warning. Please contact a dealer. |
| 3200-3217 | Engine Fuel Delivery PressureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced an engine high fuel pressure alarm. / …an engine low fuel pressure alarm. / …an engine fuel pressure alarm. / …an engine high fuel pressure warning. / …an engine low fuel pressure warning. (each ending 'Please contact a dealer.') |
| 3301-3304 | Engine Oil PressureAlarm | The generator has experienced an engine low oil pressure alarm. Please contact a dealer. / The generator has experienced an engine oil pressure alarm. Please contact a dealer. |
| 3400-3417 | Engine Intake Manifold #1 PressureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | High intake manifold pressure alarm / low intake manifold pressure alarm / intake manifold pressure alarm / high intake manifold pressure warning / low intake manifold pressure warning (each '…Please contact a dealer.') |
| 3500-3517 | Engine Intake Manifold 1 TemperatureAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced a low intake manifold temperature alarm. Please contact a dealer. / The generator has experienced a low intake manifold temperature warning. Please contact a dealer. |
| 3803-3817 | Battery Potential / Power Input 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced a battery voltage alarm. Please contact a dealer. / The generator has experienced a battery voltage warning. Please contact a dealer. |
| 4101 | Engine Position SensorAlarm | The generator has experienced an engine primary sync loss. Please contact a dealer. |
| 4201 | Engine Timing SensorAlarm | The generator has experienced an engine secondary sync loss. Please contact a dealer. |
| 4300-4317 | O2 SensorAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced an O2 sensor alarm. Please contact a dealer. / The generator has experienced an O2 sensor warning. Please contact a dealer. |
| 4503-4507 | Engine Ignition Coil #1AlarmCovered in this table | The generator has experienced an engine ignition coil alarm. Please contact a dealer. |
| 4603-4607 | Engine Ignition Coil #2AlarmCovered in this table | The generator has experienced an engine ignition coil alarm. Please contact a dealer. |
| 4900-4917 | Engine Fuel Valve 1 PositionAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced an engine fuel valve alarm. Please contact a dealer. / The generator has experienced an engine fuel valve warning. Please contact a dealer. |
| 5100-5117 | Engine SpeedAlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced an engine speed alarm. Please contact a dealer. / The generator has experienced an engine speed warning. Please contact a dealer. |
| 5200-5217 | Cylinder Head Temperature 1AlarmCovered in this tableType as printed: ALARM/WARNING (as printed) | The generator has experienced a cylinder head temperature alarm. Please contact a dealer. / The generator has experienced a cylinder head temperature warning. Please contact a dealer. |
| 5303-5304 | Engine Fuel Shutoff 2 ControlAlarmCovered in this table | The generator has experienced an engine fuel shutoff control alarm. Please contact a dealer. |
| 5415-5417 | Engine Oil LevelWarningCovered in this table | The generator has a high oil level warning. Remove loads, let generator cool, check oil level and drain oil if necessary before restarting. If alarm reappears, please contact a dealer. / The generator has a low oil level warning. Remove loads, let generator cool, check oil level and add oil if necessary before restarting. If alarm reappears, please contact a dealer. (Mobile Link text as printed, including its 'before resetarting' typo in the high-level variant, normalized here to 'before restarting') |
| 7000 | Overload CooldownWarning | The generator has experienced an overload and is in cool down mode. If condition persists, contact a dealer. |
Codes 3803–3817 — what the battery-voltage range costs
The 3803–3817 range (“Battery Potential / Power Input 1”) is verified as a battery-voltage family in Generac's own dealer-code table, but Generac publishes nothing more about it — no trigger, no owner action, no part. Its cost block is therefore a dealer-tier block only, stated as plainly as the battery codes that do have pages:
What it costs — codes 3803–3817
- Free fix — none documented
- No free fix is documented. Generac publishes no trigger threshold, no self-clear condition, and no owner action for this range. The Mobile Link message for this family tells the owner to contact a dealer.
- The part
No owner-replaceable part is identified for this family in any Generac source. Generac does not split the individual codes inside this range, so no part can be named for a single code inside it.
- At a dealer
No published price exists for this fault family.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What the table-only ranges cost
The remaining ranges in the table above have no page of their own, so their cost blocks live here, stated at range level exactly as Generac publishes the ranges. Most are dealer-tier only: Generac prints no trigger, no owner action, and no part for them, and no published price exists for any single one — each block states that directly, with the same published diagnostic figures the code pages carry. The one exception is 5415–5417 (Engine Oil Level), whose own Mobile Link messages print the owner's oil-level actions.
What it costs — codes 1000-1006 (Controller Fault)
- Free fix — none documented
- No free fix is documented. The Mobile Link message reports an internal alarm on the controller and tells the owner to contact a dealer.
- The part
No part is priced for this range. The controller is integrated and model-specific, and Generac publishes no part number for it.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 1800-1801 (Overvoltage)
- Free fix — none documented
- No free fix is documented. This is a table-level entry with a dealer-directed message. Generac's Guardian table lists 1800 only — that overlap is shown, not merged.
- The part
Generac publishes no part number for this code, so no part can be priced for it.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 2094-2099 (Wiring Error)
- Free fix — none documented
- No free fix is documented. Both Mobile Link messages for this range end with “Please contact a dealer.” Wiring correction is qualified-technician work, and we publish no wiring information for this family.
- The part
Generac publishes no part number for this code, so no part can be priced for it.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 3100-3117 (Engine Throttle Valve 1 Position 1)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. Throttle components are dealer-level remedies, and Generac publishes no part number for them.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 3200-3217 (Engine Fuel Delivery Pressure)
- Free fix — none documented
- No free fix is documented. Generac publishes no per-code thresholds for this range.
- The part
No part is priced for this range. Fuel-system pressure work is dealer-level, and no part number is published.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 3400-3417 (Engine Intake Manifold #1 Pressure)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. The sensor family is named without part numbers in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 3500-3517 (Engine Intake Manifold 1 Temperature)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. The sensor family is named without part numbers in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 4300-4317 (O2 Sensor)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. Generac publishes no O2 sensor part number for it.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 4503-4507 (Engine Ignition Coil #1)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. Ignition coils are named without part numbers in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 4603-4607 (Engine Ignition Coil #2)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. Ignition coils are named without part numbers in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 4900-4917 (Engine Fuel Valve 1 Position)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. The fuel valve is named without a part number in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 5100-5117 (Engine Speed)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
Generac publishes no part number for this code, so no part can be priced for it.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 5200-5217 (Cylinder Head Temperature 1)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. The sensor family is named without part numbers in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 5303-5304 (Engine Fuel Shutoff 2 Control)
- Free fix — none documented
- No free fix is documented. Generac publishes no thresholds and no owner actions for this range.
- The part
No part is priced for this range. The fuel shutoff control is named without a part number in Generac's sources.
- At a dealer
No published price exists for this fault.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
Diagnosis comes first, before any part can be named. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
What it costs — codes 5415-5417 (Engine Oil Level)
- $0 — if correcting the oil level resolves it
- Generac's own table prints the owner actions in this range's Mobile Link messages. High level: remove loads, let the generator cool, check the oil level, and drain oil if necessary before restarting. Low level: remove loads, let the generator cool, check the oil level, and add oil if necessary before restarting. Either message ends the same way: if the alarm reappears, contact a dealer. Generac does not assign which code inside this range is high and which is low. If correcting the oil level resolves it and the warning does not reappear, the cost is $0.
- The part
For the low-level case, the owner purchase is top-up oil.
Generac 5W-20 GEO full synthetic engine oil (top-up)Part number: A0001412864 (case of 12 quarts, per Generac parts manuals)
- UGPUS lists it at $18.50 per quart (list $22.99).
- Conversion of Energy lists it at $20.75 per quart (a secondary figure).
- Next Generation capacity with filter: 1.4 quarts (10 kW), 2.5 quarts (14/18 kW), 2.2 quarts (22–28 kW).
- At a dealer
Per Generac's own messages, a warning that reappears after the oil level is corrected goes to a dealer.
Published diagnostic-visit figures: $45–$100 (Generator Repair Finder); a $125 flat trip and diagnostic fee (Maple Valley Generator); a $179 flat diagnostic fee (Treasure Coast Generators).
No dealer price specific to this family is published. Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
Ranges stay ranges
Much of the Next Generation table is engine-control (ECM-style) code ranges — 3100–3117, 3200–3217, 3301–3304, and a dozen more. Generac publishes each range under one displayed alarm with combined alarm/warning message variants and does not say what distinguishes the individual codes inside a range. Sites that list a separate meaning for, say, 3302 versus 3303 are going beyond Generac's own publications. Where a range matters most we give it a page of its own — 3301–3304 Engine Oil Pressure is the Next Gen counterpart of Guardian's 1300 — and the rest stay in the table above.
3301 / 3302 / 3303 / 3304 individual meanings: UNVERIFIED — verified negative: no Generac source read separates them; only the 3301-3304 range, one displayed alarm ('Engine Oil Pressure'), ALARM type, and two Mobile Link message variants are published. No psi threshold for the Next Gen oil-pressure family was found in a Generac source.
Individual codes inside every ECM-style range (3100-3117, 3200-3217, 3400-3417, 3500-3517, 3803-3817, 4300-4317, 4503-4507, 4603-4607, 4900-4917, 5100-5117, 5200-5217, 5303-5304, 5415-5417) and inside 1000-1006: UNVERIFIED — Generac publishes these as ranges with combined ALARM/WARNING types and message variants only. The ranges' structure resembles SPN/FMI-style engine codes, but Generac does not say so, so no FMI-style split is inferred.
Guardian codes that do NOT carry over
Code 1300 — Guardian only
Guardian Low Oil Pressure. ABSENT from the Next Generation table; Next Gen oil pressure is 3301-3304. Do not apply 1300 to Next Gen.
Code 1500-1521 — Guardian only
Guardian RPM Sensor range per the dealer-code table. Next Gen's RPM code is 1522 only.
Code 1400 — Guardian only
Guardian High Temperature — no 1400 row in the Next Gen table (Next Gen temperature faults appear as the ECM families 3500-3517 / 5200-5217, and the owner's manual names a HIGH TEMPERATURE alarm without a number). Do not assign 1400 to Next Gen.
Guardian owners: code 1300 Low Oil Pressure and the RPM Sense Loss family page cover the Guardian side.
Shared with Guardian — and overlaps we refuse to merge
A code counts as shared here only where a Generac source itself applies it to the Next Generation line with the same alarm and meaning. Seven codes meet that bar:
| Code | Alarm | Evidence (per Generac) | Pages |
|---|---|---|---|
| 1100 | Overcrank | Dealer-code article: Next Gen table '1100', Guardian table '1100, 1101', both ALARM/Overcrank. Dedicated Overcrank article Environment: 'Generac Guardian series and Next Generation Air-Cooled Standby series', one meaning (cranks 5 times without starting). NOTE the asymmetry: 1101 is Guardian-only as printed. | Next Gen · Guardian |
| 1600 | Underspeed | Dealer-code article: Next Gen '1600', Guardian '1600, 1603', both ALARM/Underspeed. 1603 is Guardian-only as printed. | Next Gen · Guardian |
| 2100 | Overload Remove Load | Dealer-code article: both tables list 2100 ALARM (Guardian table also shows a 2100-2103 row). Next Gen owner's manual Quick Reference gives the same owner action for the name. | Next Gen · Guardian |
| 2750 | Low Battery | Battery-alarms article Environment covers Next Generation 10-28 kW AND Guardian 10-26 kW with one trigger (below 12.1 VDC). Also in both dealer-code tables. Generac's articles also conflict on this code's type — see Conflicts and discrepancies. | Next Gen · Guardian |
| 2760 | Battery Problem | Battery-alarms article (both series): >16 V or charger current >600 mA at end of an 18-hour charge cycle. In both dealer-code tables as WARNING. | Next Gen · Guardian |
| 2770 | Charger Warning | Battery-alarms article (both series): below 12.5 V at end of an 18-hour charge cycle. In both dealer-code tables as WARNING. | Next Gen · Guardian |
| 2780 | Charger Missing AC | Dedicated 2780 article covers both series (T1 circuit, expected 120 VAC) — BUT with documented Next Gen differences: Mobile Link-only display on Next Gen, and the Next Gen nuisance-warning behavior. Shared code, series-specific behavior. | Next Gen · Guardian |
Four more cases overlap without a Generac source asserting the two series' entries are identical, so we record them as overlaps only:
- 1200-1207 overlap (Overspeed): Next Gen table prints 1200-1208; Guardian prints 1200-1207; the dedicated Overspeed article is titled 1200-1207 and covers both series. The overlapping range is very likely shared, but because the Next Gen table's printed range differs, the overlap is shown as an overlap only, not asserted as an identical-meaning shared range.
- 1900-1906 overlap (Undervoltage): Next Gen table prints 1900-1907; Guardian prints 1900-1906; dedicated article (both series) lists 1900-1906 under a 1900-1916 title. Same treatment as Overspeed.
- 1800 (Overvoltage): Guardian table lists 1800 alone; Next Gen lists 1800-1801. 1800 appears in both under the same alarm name/type, but no Generac source states the Next Gen 1800 is the same fault as the Guardian 1800 — shown as overlap only.
- 2098/2099 vs 2094-2099 (Wiring Error): Guardian lists 2098 and 2099 individually; Next Gen lists the range 2094-2099 with two Mobile Link messages. Same displayed alarm name; per-code identity NOT asserted.
Where Generac's own sources disagree
Generac's articles do not always agree with each other. We preserve every conflict we found as a labeled conflict — on the affected code pages and here — instead of silently picking a winner:
Alarm names in the owner's manual — with no code
The Next Generation owner's manual (10-28 kW) Section 5 Quick Reference Guide lists alarm NAMES (no numeric codes, except the two shutdown switches) with LED, problem, action and solution. Names: HIGH TEMPERATURE (red), OVERLOAD REMOVE LOAD (red), RPM SENSE LOSS (red), LOW OIL PRESSURE (red), OVERCRANK (red), LOW VOLTS REMOVE LOAD (red — no corresponding displayed alarm in the dealer-code Next Gen table under that exact name; do not assign it a code), OVERSPEED (red), UNDERVOLTAGE (red), UNDERSPEED (red), STEPPER OVERCURRENT (red — likewise no Next Gen table row under that name; the Guardian-era stepper code is not imported), WIRING ERROR (red), OVER-VOLTAGE (red), SHUTDOWN SWITCH (2800) (flashing red), SHUTDOWN SWITCH (2801) (flashing red), LOW BATTERY (yellow), BATTERY PROBLEM (yellow), CHARGER WARNING (yellow), CHARGER MISSING AC (yellow), SERVICE A / SERVICE B / SERVICE C (yellow, maintenance), INSPECT BATTERY (yellow, maintenance reminder).
Battery and upkeep for Next Generation
Which battery a Next Gen unit needs
Next Generation takes a BTX30L AGM battery (400 CCA minimum) — not the Guardian 26R — and one Generac manual prints a BTX20L / 310 CCA spec instead. Both statements are on the battery page, labeled as the unresolved conflict they are.
Read the battery page →Battery & Maintenance Kit Finder
Pick your series and size to get the verified battery, the scheduled maintenance kit (7216 for 14–28 kW, 6482 for the 10 kW), oil, and filters Generac publishes for it.
Open the finder →Set exercise time on Power Zone 200
Exercise on Next Generation is set through Mobile Link rather than the controller — how it works, and what a missed exercise means.
Read the exercise guide →Guardian codes live here →
This hub is Next Generation only. Guardian (Evolution/Nexus) fault codes — including 1300 and the 1500-series RPM codes that do not apply to Next Gen — are in the separate Guardian hub, cited to Generac's diagnostic manual and support articles.
Go to the Guardian hub →Sources
- What Error Codes Do I Need to Call a Dealer For? — Generac (support.generac.com) (Next Generation Series Error Codes table (Displayed Alarm | Alarm/Warning | E-code | Message in Mobile Link); Environment; Troubleshooting (clearing procedure))
- Generac Home Standby Error Codes: Red/Yellow Light Meanings, Mobile Link Messages & Fixes — Generac (support.generac.com) (Environment: 'Power Zone 200: These controllers do not have a display. Error messages can only be viewed in the Mobile Link app.')
- What is the Power Zone 200 Controller for Generac home standby generators? — Generac (support.generac.com) (Entire article (introduction date, replaces Evolution 2.0, no screen, functions, modes))
- Owner's Manual for 60 Hz Air-Cooled Generators — 10 kW to 28 kW (Next Generation), OMNL G 10-28KW 60HZ Y20 EN, Item A0004332577 — Generac Power Systems (manual reproduction via manuals.plus; Generac document) (Section 5, Quick Reference Guide + External LED Indicators table)
- What is the difference between maintenance reminders, warnings, and alarms? — Generac (support.generac.com) (Warnings note: Guardian solid YELLOW vs Next Generation flashing YELLOW; Alarms; Maintenance reminders)
- Troubleshooting home standby battery alarms and error codes — Generac (support.generac.com) (Environment: Next Generation 10–28 kW AND Guardian; Low Battery / Very Low Battery / Battery Problem / Charger Warning triggers)
- Battery voltage is very low fault (2751) — Generac (support.generac.com)
- What Does It Mean When My Generator Displays an Error Code: Charger Missing AC, Code 2780? — Generac (support.generac.com)
- What Does It Mean When My Generator Displays an Error Code: Auxiliary Shutdown, Error Code 2800? — Generac (support.generac.com) (Next Generation Series air-cooled generators section; Power Zone 200 clearing warning)
- What Does It Mean When My Generator Displays an Error Code: Overcrank, Code 1100-1101 — Generac (support.generac.com) (Environment: Guardian AND Next Generation)
- What Does It Mean When My Generator Displays an Error Code: RPM Sense Loss (1500–1522) — Generac (support.generac.com) (“RPM sensor errors include error code numbers 1500 through 1522”)
- What Does It Mean When My Generator Displays an Error Code: Undervoltage, Code 1900-1916 — Generac (support.generac.com) (Environment: Next Generation AND Guardian; body lists error codes 1900–1906)
Safety note: StandbyWise publishes lookup information only — no gas-line, transfer-switch wiring, or internal repair instructions. Dangerous faults are gated to licensed-dealer referral on every code page. See our disclaimer.