Skip to content
StandbyWise

How Generator Sizing Works

There is no honest one-line rule for what size generator a house needs — anyone sizing from square footage alone is guessing. The method installers actually use, and the one our calculator follows, is a load worksheet. This page explains the method, the one derating fact that changes the answer for most homes, and what each size class roughly covers.

Skip to the worksheet

The Generator Sizing Calculator is the worksheet, ready to fill in: check the loads you want backed up, adjust wattages to your appliances' nameplates, pick your AC tonnage, and get a size range with the margin stated on screen.

The load worksheet method

  1. List what must run in an outage. Not everything in the house — the loads you actually need: refrigeration, heating system fan or controls, well/sump pumps, lighting circuits, medical or work essentials, and whatever else makes the outage livable.
  2. Add running watts, load by load. Use each appliance's nameplate wattage where you can. Our calculator's defaults are typical estimates — clearly labeled, and editable for exactly this reason. Motors (pumps, AC compressors) also draw a brief starting surge above their running watts, which is part of why headroom exists.
  3. Treat central AC as the decision-maker. For most homes the air conditioner is the single largest load and the difference between size classes. Our worksheet uses an editable estimate of 1,800 watts per ton of central AC — an estimate, labeled as such, not a manufacturer figure.
  4. Apply headroom, then round up to a real size class. Our worksheet adds a 20% margin (stated on its results screen) for starting surges and future loads, then maps the total to the generator classes that actually exist: 10, 14, 18, 22, 24, 26, and 28 kW.
  5. Check the fuel derating before you commit — see below. The class on the box is the propane rating; on natural gas the same unit produces less.

The derating fact: natural gas lowers the rating

Standby generators are rated on propane (LP). On natural gas (NG), output drops — per Generac's own specifications, the Guardian 22 kW is a 19.5 kW generator on natural gas. Every size in our fuel consumption chart shows both ratings side by side (for example, the Guardian range runs 9 kW NG at the 10 kW size up to 22.5 kW NG at the 26 kW size). If your worksheet total lands near the top of a class and you run on natural gas, the derated rating — not the headline number — is the one to compare against.

Rating source (Guardian 22 kW)

Size classes, roughly

The descriptions below are rough orientation only — typical coverage patterns, not promises for your home. Two houses with identical square footage can land two classes apart depending on AC size, heating type, and what is on the load list. The worksheet is the method; this table just helps you read its answer.

Class (LP rating)Rough coverage — estimate
10 kWEssentials coverage for a smaller home: refrigeration, lights, a well or sump pump, furnace fan, and a few circuits — not whole-house AC.
14 kWEssentials plus more circuits; may carry a smaller central AC depending on the actual load list.
18 kWMid-range whole-house coverage for many homes, typically including one central AC — the worksheet decides, not the label.
22 kWThe most common whole-house class: full panel coverage for many homes with one large or two smaller AC systems, subject to the load list.
24 kWWhole-house coverage with more headroom for larger AC, electric cooking, or added loads.
26–28 kWLargest air-cooled class: big homes, multiple AC systems, or high simultaneous loads. Beyond this, sizing is a dealer load-calculation conversation.

Why we do not size by square footage

Square footage correlates weakly with electrical load: it says nothing about AC tonnage, electric versus gas heat and cooking, well pumps, or how much of the house you want backed up. Rules like “X watts per square foot” produce false precision — a confident number built on the wrong input. If a rough starting guess is all you want, the honest version is the size-class table above; if you want an answer you can buy against, spend five minutes on the worksheet calculator — and know that a dealer's formal load calculation for your panel is the final word before any installation. Our worksheet is an estimate to plan with, not a substitute for that calculation, and it contains no transfer-switch or gas-line sizing guidance.