Code 1100 — Overcrank

Your generator cranked and cranked but never started. Generac's own explanation, the causes it lists, and the only owner checks it publishes for this alarm are below — everything beyond them is dealer work.

Verified against a Generac sourceALARM · Red light
What this code means
Unit turns over but will not start. The engine will attempt to crank 5 times; if it is unable to start, an OVERCRANK alarm is triggered.
What triggers it
Engine cranks through its attempts (5 per the dedicated article) without starting.
Which generators it applies to
  • Guardian Series (Evolution / Nexus) — article applies to Guardian and Next Generation
  • Next Generation Series (Power Zone 200)
Causes Generac lists
  • Issues with the fuel supply system or lack of routine maintenance
  • Inadequate fuel pressure
  • Fuel shutoff valve is OFF
  • Improper fuel selection in the controller (Evolution) or in the Field Pro app (Power Zone 200)
  • Air filter issue
  • Improper installation
  • Low battery
Owner-level checks Generac lists
  • Verify the fuel line shutoff valve is ON
  • Clear the alarm and restart the unit in MANUAL (never start a generator while under load)
  • If issues persist after checks and restart, contact a Generac IASD

These are only the checks Generac itself lists for owners. Anything beyond them — internal wiring, fuel-pressure testing, transfer-switch internals, or internal repair — is dealer work, and we do not publish instructions for it.

Series differences and source notes — read carefully
Dealer-code table lists Guardian as 1100, 1101 and Next Generation as 1100 only. Dedicated article covers 1100-1101 for both series named in its Environment section.
Dealer-only territory. Do not attempt to clear this fault and repeatedly restart the unit. If it returns after one clear-and-restart, or you are unsure it is safe to run, stop and contact a licensed Generac dealer or installer (Generac calls them IASDs). If you smell gas, hear hissing, or suspect carbon monoxide, leave the area and call your gas utility or emergency services first.For this code: Fuel pressure checks and any remedy beyond the listed basic checks are dealer-level in the source; not transcribed.