Code 2760 — Battery Problem

Next Generation (Power Zone 200) only. This page covers the Next Generation version of this fault. The Power Zone 200 controller has no display — the code and message appear only in the Mobile Link app — and its codes, thresholds, and clearing procedure are not interchangeable with Guardian (Evolution) units, even where a code number exists on both series. Guardian codes live in the Guardian error-code hub.

What Generac's own Next Generation code table and articles say about code 2760 — its Mobile Link message, its documented trigger where Generac publishes one, and when it is a dealer call — is below. Anything beyond owner-level observation is dealer work.

Verified against a Generac sourceWarningWARNING — as printed in Generac's Next Generation table
What this code means
In Mobile Link, Generac words this fault as: “The battery is not charging properly. Please replace the battery or contact a dealer.”
What triggers it
Battery-alarms article (both series): activated when battery voltage exceeds 16 volts OR charger current is over 600 milliamperes at the end of an 18-hour charge cycle, suggesting a malfunctioning battery or overcharging issue.
Which generators it applies to
Generac Next Generation Series air-cooled standby generators (10–28 kW) with the Power Zone 200 controller. The Power Zone 200 has no display, so this code appears only in the Mobile Link app — Mobile Link shows both the message and the numeric code.

What it costs

$0 — if one clear-and-restart fixes it
Generac's 2760 article gives one owner step: clear the alarm and manually restart the unit. Sometimes that is all that is needed if it was a one-time occurrence. The warning triggers when battery voltage rises above 16 volts, or charger current goes over 600 milliamperes at the end of an 18-hour charge cycle. If the warning clears and does not return, the cost is $0. Generac does not recommend that owners modify or service internal wiring. Anything beyond the clear-and-restart is dealer work.
The part

The Mobile Link message for this code names the fix: replace the battery, or contact a dealer.

Generac Next Generation battery — 12V AGM, Group BTX30L, 400 CCA minimumPart number: A0010137451 / A0010137452

  • Elliott Electric Supply lists the Generac battery at $207.56.
  • Platt Electric Supply lists it at $210.42 (figure via HomeGeneratorCost.com).
  • Generac's own store publishes no price for this part.
  • An aftermarket direct replacement — the Commander CMX30L AGM battery — lists at $109.99 at Battery Warehouse. It is not the Generac-branded part.
At a dealer

A technician battery replacement costs $300–$500 all in. The battery and the labor are both inside that total. That figure is a published battery-swap total, not a price quoted for this code. Sources: Grounded Electric and Generator Repair Finder.

If the charging circuit is the cause instead, no part price applies: the charger is built into the controller, and no separate charger part is sold. Parts price only — labor varies by dealer.

Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.

This code is also a Guardian code. Battery-alarms article (both series): >16 V or charger current >600 mA at end of an 18-hour charge cycle. In both dealer-code tables as WARNING. See code 2760 on the Guardian side →
Clearing a fault on Power Zone 200. On Power Zone 200, an alarm is cleared by pressing and holding the OFF button for three seconds, then pressing AUTO. Do NOT use the Guardian OFF/ENTER sequence on this controller — Generac explicitly warns against it. Warnings are not dismissed by clearing: a warning stays until the underlying issue is resolved, and then clears itself.
How warnings clear on Next Generation. A warning does not shut the generator down, and it cannot be dismissed from the keypad — it clears itself once the underlying condition is corrected. If it persists or keeps returning, contact a licensed Generac dealer or installer rather than repeatedly clearing and restarting the unit.

Seeing a different code — or is yours a Guardian?

Browse the full Next Generation (Power Zone 200) hub for every verified Next Gen entry, use the Fault Code Lookup tool, or see the separate Guardian error-code hub — the two controllers' codes are never merged.

Sources