Generac error code family
RPM Sense Loss — Codes 1500, 1501, 1505
If your Guardian controller shows an RPM Sensor or RPM Sensor Loss alarm in the 1500s, this page is for you. It publishes exactly what Generac's own diagnostic manual verifies about this family — no more.
Stated plainly: the individual distinctions between 1500, 1501, and 1505 are not yet verified against a manufacturer source. Generac's Diagnostic Repair Manual treats 1501, 1505, 1511, and 1515 as one grouped entry, and its dealer table lists the wider 1500–1521 range under a single “RPM Sensor” label. Other websites publish confident per-code distinctions for these codes; we could not confirm any of them in a Generac source, so we do not present them as fact. What is missing is a Generac manual e-code table that lists each of these codes separately — when we read one, this page will be updated and the change noted in our corrections log.
- What is verified — the family meaning
- RPM Sensor Failure / RPM Sensor Loss. Generac's overview list gives the family's Mobile Link message as: “The generator has experienced a no crank RPM Sensor alarm. Please contact a dealer.” Generac's overview guidance also notes that an article about a code generally applies to all variants sharing its first two digits.
- What triggers it — the grouped manual description
- Manual (grouped for 1501/1505/1511/1515): during cranking, if the board does not see a valid rpm signal within three (3) seconds it will shut down and latch out on 'RPM Sensor Loss.' If the rpm signal is lost for one full second during running, the controller will shut down the engine, wait 15 seconds, then re-crank; if no rpm signal is detected within the first 3 seconds of that cranking it latches out. If a signal is detected and the engine runs, and the signal is subsequently lost again, the controller tries one re-crank attempt before latching out.
- Cause the manual names
- Manual NOTE: a common cause of RPM Sensor Loss fault is the lack of engine cranking; this could be due to a faulty crank circuit or a faulty starter
- Which generators
- Guardian Series (Evolution controller), where Generac's dealer table lists an RPM Sensor alarm range of 1500–1521. Next Generation is different: its dealer table does not list 1500 at all — its RPM Sensor entry is code 1522 (no crank) only. Do not apply the 1500 codes to a Next Generation unit.
- Owner-level checks
- None are listed for this family in the manufacturer sources we read. Generac places the RPM Sensor family on its dealer-required list.
Dealer-only territory. Do not attempt to clear this fault and repeatedly restart the unit. If it returns after one clear-and-restart, or you are unsure it is safe to run, stop and contact a licensed Generac dealer or installer (Generac calls them IASDs). If you smell gas, hear hissing, or suspect carbon monoxide, leave the area and call your gas utility or emergency services first.For this family: Crank circuit / starter diagnosis is dealer-level; not transcribed.
Check a code or compare the family
The Fault Code Lookup tool shows 1500, 1501, and 1505 with the same honesty flags used here, alongside every verified code in the database. If the unit cranks but never starts, also see the won't-start triage guide and code 1100 Overcrank.
Sources
- Diagnostic Repair Manual G0070420 — Generac Power Systems (official manual, ManualsLib reproduction) (Section 3.2 Engine Protective Devices, p.53 (ManualsLib pagination))
- How do I test my generator in manual mode after clearing an error? — Generac (support.generac.com) (What to do if the error returns (groups 1501/1505/1511/1515))
- What Error Codes Do I Need to Call a Dealer For? — Generac (support.generac.com) (Next Generation Series Error Codes table; Guardian Series Error Codes table)
- Generac Home Standby Error Codes: Red/Yellow Light Meanings, Mobile Link Messages & Fixes — Generac (support.generac.com) (Home standby generator message codes table)