Skip to content
StandbyWise

Cummins fault code · Spec B generation

Fault Code 46 — Generator Set Overload

What Cummins' own manual says about fault code 46 (“Generator Set Overload”) on the Spec B generation — its meaning, its documented trigger, and the checks Cummins itself lists — is below. Cummins documents its two control generations separately, and so do we: if your unit is the other generation, use that generation's page from the hub instead. Anything beyond the listed checks is dealer work.

Verified against a Cummins manualSpec B generationShutdownShutdown
What this code means
The generator set was overloaded.
What triggers it
Operator manual possible causes (A062J680 §6.4): generator set loads, alternator windings, wire connections. (Service-manual Logic line not read this pass.)
Which generators it applies to

RS13A (C13N6H) / RS17A (C17N6H) / RS20A (C20N6H) / RS20AC (C20N6HC), Spec B

Generation: Spec B generation — documented in Cummins manuals A062J680 (operator) / A062J683 (service).

  • Controller: Cummins RS Spec B local display (C13N6H/C17N6H/C20N6H/C20N6HC)
Checks Cummins lists
  • Reduce the number of connected loads, especially loads that require higher starting current such as air conditioners.
  • Check and service air filter as necessary.
  • Contact a Cummins service representative or an authorized Cummins dealer.

These are only the checks Cummins itself lists. Anything beyond them — internal wiring, sensors, switches, or alternator work — is dealer work, and we do not publish instructions for it.

Same code number, other generation. Code 46 also exists on the Operator Panel generation, and Cummins documents it in a separate manual entry — the meaning is the same, but the documented trigger and cause list differ (for example, thresholds stated only in the Spec B service manual). We keep the two entries separate rather than merging them: see Code 46 — Generator Set Overload (Operator Panel generation).
Before you reset anything. Identify and correct the cause first — a fault that is simply cleared will come back, and repeated cranking or restarting can cause further damage. If the code returns after the checks Cummins lists above, contact a Cummins service representative or an authorized Cummins dealer.

Seeing a different code — or a different brand?

Browse the full Cummins error-code hub for both Cummins generations, or search any brand with the Fault Code Lookup tool (choose the Cummins tab — results stay split by generation). Other brands live in their own hubs — Generac error codes and Kohler error codes and Briggs & Stratton error codes and Champion fault indications — brands' codes are never merged, and Cummins code numbers do not carry over to other brands.

Cummins source