Skip to content
StandbyWise

Champion fault indication · aXis / fleX

Champion “Line Under Voltage” — What This Fault Indication Means

Champion standby generators have no error codes — “Line Under Voltage” is a named LED or icon, and Champion documents it separately on 2 controller generations with different thresholds and wording. Each generation's section below states its own manual's version; they are never blended into one answer. Anything beyond the owner checks Champion lists is dealer work.

Verified against a Champion manualGeneration 2 — aXis Controller (fault icons)Generation 3 — fleX Controller (OLED fault icons)Named indication — Champion uses no fault codes
Generation differences — read the section for your controller. This is one of the biggest generation differences in the Champion line: the aXis limit is 190 VAC, while the fleX limit is 216 VAC lasting 0.5 seconds, evaluated after 10 seconds of running. Never apply one generation's number to the other. The manual remedy on both is an AVR adjustment (“Set Voltage to 240 VAC”) — dealer/installer work, recorded as a gate, not an owner step.

Generation 2 — aXis Controller (fault icons) — “Line Under Voltage”Shutdown

How it shows
RED icon (controller + exterior fault LED)
What triggers it
Generator output below preset limit of 190 VAC.
What the generator does
Shutdown; re-start disabled (latching).
Dealer gate (aXis). Manual remedy is 'Check and adjust AVR. Set Voltage to 240 VAC' — dealer/installer work, recorded as a gate.

Champion source for this section: 100515 Operator's Manual p. 18; aXis Installation Manual p. 32

Generation 3 — fleX Controller (OLED fault icons) — “Line Under Voltage”Shutdown

How it shows
Icon lit; warning LED on controller and exterior lit
What triggers it
Generator output below preset limit of 216 VAC lasting 0.5 seconds; condition evaluated after running 10 seconds. (DIFFERS sharply from aXis 190 VAC — see conflicts.)
What the generator does
Shutdown; re-start disabled (latching); icon remains lit until corrected.
Dealer gate (fleX). Manual remedy 'Check and adjust AVR. Set voltage to 240 VAC' + contact Champion/Authorized Dealer — dealer/installer work, recorded as a gate.

Champion source for this section: 201391 Operator's Manual p. 26

Resetting after you correct the fault. On aXis and fleX controllers, Champion's “Fault Code Reset” is: push the OFF button to reset, then MAN or AUTO to re-arm (fleX: AUTO or MAN). On the earlier ECM units, placing the Engine Control Module switch in the OFF position resets the fault LED. Correct the fault first — an indication that is simply cleared will come back, and on fleX Over Crank the 120-second starter lockout must count down before another start attempt.

If you smell gas, hear hissing, or suspect carbon monoxide at any point, leave the area and call your gas utility or emergency services first — before any fault checks.

Seeing a different indication — or a different brand?

Browse the full Champion fault-indication hub for all three Champion generations, or search any brand with the Fault Code Lookup tool (choose the Champion tab — results stay split by generation, and Champion results are named indications, never codes). Other brands live in their own hubs — Generac error codes, Kohler error codes, Cummins error codes and Briggs & Stratton error codes — brands are never merged.

Sources