Kohler RDC2 fault message — liquid-cooled (TP-6905)
IAT Volt Lo
What Kohler's TP-6905 operation manual says about the “IAT Volt Lo” message — its meaning, its documented trigger, and the checks Kohler itself lists — is below. Anything beyond those checks is dealer work.
- What this message means
- OnCue Plus name: 'Iat Low Voltage'. The ECM reported an Engine Air Temperature/Manifold Absolute Pressure Sensor (TMAP) error. (A TP-6905 6/14 partial reproduction also lists an 'IAT Volt Hi' row; the 4/16b table read here lists only Volt Lo — edition difference, see conflicts_preserved.)
- What triggers it
- ECM-reported TMAP sensor error (low voltage).
- Which generators it applies to
24RCL, 30RCL, 38RCLB (RDC2, liquid-cooled)
- Controller: RDC2 (TP-6905, liquid-cooled RCL)
- Checks Kohler lists
- Contact an authorized distributor/dealer for service and provide the fault code.
These are only the checks Kohler itself lists. Anything beyond them — internal wiring, sensors, switches, or alternator work — is dealer work, and we do not publish instructions for it.
What it costs
- Free fix — none documented
- None documented. Dealer service, with the fault code, is the only listed action — an ECM-reported TMAP sensor error. Edition note: a partial reproduction of TP-6905 also lists an “IAT Volt Hi” row; the full table read for this site lists only Volt Lo, so no cost block exists for Volt Hi.
- The part
No part is priced for this message. The TMAP sensor is named without a part number in Kohler's manuals.
- At a dealer
Published Kohler service figures — none is specific to this message, because no dealer publishes a price for a single fault message: a $595 single service visit for liquid-cooled units, plus tax (HomeSafe Generators & Electrical); a $249 service call including travel and up to 60 minutes of on-site diagnosis (GSHA Services). Published plan figures — $249–$499 per year (Four Seasons) and $300 per year for two visits a year (Watts Up Electric) — are published for air-cooled residential service.
Parts price only — labor varies by dealer.
Every price on this page was checked in November 2026 against the source named next to it. Prices change; the part numbers do not.
Seeing a different message — or a Generac code?
Browse the full Kohler error-code hub for every verified RDC2 message and the legacy ADC/DC codes, use the Fault Code Lookup tool, or see the separate Generac error-code hub — the two brands' codes are never merged.
Kohler source
- TP-6905 4/16b — Operation, Residential/Light Commercial Generator Sets, Models 24RCL, 30RCL, 38RCLB; Controller: RDC2 — Kohler Co. (ManualsLib reproduction of the Kohler manual) (Figure 2-5 Controller Fault Messages, Section 2, pp. 25–28)