Costs
Generac Guardian 18 kW Fuel Consumption & Running Cost
Fuel consumption for the Guardian Series 18 kW, transcribed from Generac's own spec sheet — nothing interpolated, nothing carried over from another size or series. This model is rated 18 kW on propane and 17 kW on natural gas, with a 816cc G-Force 800, 2 cylinder engine.
Consumption (Generac spec)
| Fuel | 50% load | 100% load |
|---|---|---|
| Natural gas | 169 ft³/hr | 247 ft³/hr |
| Propane (LP) | 1.7 gal/hr (62 ft³/hr) | 3.02 gal/hr (110 ft³/hr) |
Sources
- SPEC 10-18kW GUARDIAN HSB EN (A0000973374) — Guardian 10/14/18 kW Specification Sheet — Generac Power Systems (official spec sheet; values read from the spec-sheet table) (Specifications — Generator / Engine tables (10, 14, 18 kW columns). Note: this item number is the Downloads/Manuals listing on the Generac 18kW product page.)
- 18kW Guardian Series Home Generator | 7226 — Generac (generac.com product page) (Specifications)
Note from the source data: Generac's 18 kW product page erroneously repeats 169 ft3/hr for NG at 100% load; the Guardian 10/14/18 spec sheet value of 247 ft3/hr is used.
Worked running-cost example
Costs depend on your local fuel price, which we do not guess. The figures below use example prices only — natural gas at $1.50 per therm (1 therm = 100 ft³) and propane at $3.00 per gallon, the same starting defaults as our fuel cost calculator. Substitute your own bill's price for the real number.
| Fuel (example price) | Cost/hr at 50% load | Cost/hr at 100% load |
|---|---|---|
| Natural gas ($1.50/therm) | $2.54/hr | $3.71/hr |
| Propane ($3.00/gal) | $5.10/hr | $9.06/hr |
- A 24-hour outage at 50% load on natural gas: 169 × 24 = 4,056 ft³ = 40.56 therms ≈ $60.84 at the example price.
- The same 24 hours at 50% load on propane: 1.7 × 24 = 40.8 gallons ≈ $122.40 at the example price.
Real outages sit between the two load columns, so treat 50% and 100% as the floor and ceiling of the range. For your own outage length and fuel price, run the Fuel & Running Cost Calculator — it uses these same verified figures.
Comparing series? The Next Generation Series 18 kW burns different amounts
Generac publishes different consumption for the same kW size in each series (natural gas: 164/235 ft³/hr at 50%/100% load). See the Next Generation 18 kW fuel page.
All models
Per-model pages for every size Generac publishes verified figures for — or the full fuel consumption chart with both series side by side.