Skip to content
StandbyWise

Generator sizing

What Size Generator Do You Need for a 4-Ton Air Conditioner?

The air conditioner is usually the largest single load a standby generator has to start, so its tonnage drives the size decision more than any other line on the worksheet. At 4 tons, the AC alone is a third or more of a typical worksheet total. This page runs the worksheet three ways — essentials only, whole-house circuits, and whole-house plus an electric water heater.

The worksheet estimates a 4-ton AC at 7,200 running watts (1,800 W per ton — a typical worksheet estimate, not a manufacturer figure). Starting current is the real constraint: a compressor's brief start surge runs well above its running watts, which is part of what the 20% headroom margin is for. Your AC's nameplate, or a dealer's measurement, governs.

The worksheet, run three ways

Each row is the same worksheet our sizing calculator runs: add the backed-up loads, add the AC at the worksheet estimate of 1,800 running watts per ton, apply a 20% headroom margin for motor starting surges and future loads, then round up to a Generac air-cooled size class that actually exists (10 / 14 / 18 / 22 / 24 / 26 / 28 kW, propane ratings).

ProfileLoadsAC (4 ton)TotalWith 20% marginSize class
Essentials only4,200 W7,200 W11,400 W13,680 W14 kW
Whole-house circuits, gas water heat8,300 W7,200 W15,500 W18,600 W22 kW
Whole-house circuits + electric water heater12,800 W7,200 W20,000 W24,000 W24 kW

Wattages are the calculator's typical-estimate defaults, labeled as estimates there and here — confirm any load that matters against its appliance nameplate.

What the whole-house profile includes

The middle and bottom rows back up these loads (the essentials profile is the first four):

LoadRunning watts (worksheet estimate)
Refrigerator700 W
Gas furnace blower / air handler800 W
Microwave1,200 W
Lighting & general outlets (whole-home allowance)1,500 W
Standalone freezer500 W
Dishwasher1,200 W
Washing machine1,200 W
Garage door opener500 W
TV & entertainment300 W
Home office (computer, monitor, router)400 W

What moves the answer

Any one of these can push a home up a class — electric resistance loads most of all. If several are on your list, expect the class above the table's answer, or a load-management plan from the installer:

Running on natural gas? Read the lower rating

Size classes are propane (LP) ratings. On natural gas the same unit produces less — per Generac's specifications, the Guardian 22 kW is a 19.5 kW generator on natural gas. If your worksheet total with margin lands near the top of a class and you run on natural gas, compare the total against the derated rating, not the headline number. Every size in our fuel consumption chart shows both ratings side by side.

Rating source (Guardian 22 kW)

Run it with your own loads

These profiles are typical, not yours. The Generator Sizing Calculator is the same worksheet with your appliances and your AC tonnage, and how generator sizing works explains the method in full. A dealer's load calculation for your panel is the final word before buying — this worksheet is an estimate to plan with. Once you know your class, the installed cost guide prices it.

Related sizing questions

Safety note: this worksheet is an estimate, not a substitute for a dealer's load calculation. StandbyWise does not provide instructions for gas-line work, transfer-switch wiring, or internal generator repair. See our disclaimer.