Generac Maintenance Schedule

This is Generac's own published schedule, transcribed in full — not a dealer's summary of it. Generac Next Generation Series 10-28 kW air-cooled and Generac Guardian Series 10-26 kW air-cooled (2017 to present), per Generac support. Generac states the table is an example/for reference — the model's owner's manual maintenance section governs. Generac presents the table as an example for reference; your model's owner's manual governs if anything differs.

Not sure what is due on your unit right now?

Enter your run hours and last-service timing into the Maintenance Due Calculator — it works directly from this schedule. For the parts each service needs, see the Battery & Maintenance Kit Finder and the kit 6485 page.

The schedule, as Generac publishes it

TaskDaily if running continuously or before each useEvery YearSchedule A — every two years or 200 hoursSchedule B — every four years or 400 hours
Inspect enclosure louvers for dirt and debris *●———
Inspect lines and connections for fuel or oil leaks●———
Check engine oil level●———
Inspect for water intrusion **—●——
Perform fuel system leak test—●——
Check battery condition, electrolyte level, and state of charge——●—
Replace engine oil and oil filter †——●●
Replace engine air filter———●
Clean; inspect spark plug gap; replace if necessary———●
Inspect/adjust valve clearance (where applicable) ‡———●
Inspect/clean sediment trap—See local codes and guidelines——

The periods, in plain terms

Break-in / Schedule C

After the first 25 hours of run time (PowerPact 7.5 kW: first 20 hours)

Change engine oil and oil filter after the break-in period. Units ship with conventional oil; do not switch to synthetic before break-in is reached. 'Schedule C' designation is used for Next Generation series.

Yearly maintenance

Every 100 hours or every year, whichever comes first

Includes water-intrusion inspection and fuel system leak test (see yearly column).

Schedule A

Every 200 hours or every two years, whichever comes first

Oil and oil filter replacement; battery condition/electrolyte/charge check.

Schedule B

Every 400 hours or every four years, whichever comes first

Schedule A items plus air filter replacement, spark plug clean/gap-inspect/replace, valve clearance where applicable.

Continuous use

Daily (every 24 hours of continuous running)

Daily-column checks apply when running continuously or before each use.

Important notes from Generac